DESCRIPTION
Operation, Maintenance and Service Manual. User Responsibility. Ohmeda Medical recommends that a telephone or written request for service advice be made to the nearest Ohmeda Medical Regional Service Center. This Product or any of its parts should not be repaired other. Meter shows how long the unit has been operated. Ohmeda Biliblanket Meter Manual OHMEDA BILIBLANKET METER II MANUAL. When you buy an item, ohmeda biliblanket meter ii manual always has the package. The owner's manual usually. Find your owner's manual and get detailed information about datex ohmeda Ready to read online or download ohmeda biliblanket meter ii manual, free. V.EN Firefly. User manual DO NOT carry the Firefly while the patient is in the device. DO NOT place the patient directly on the window of the lower light. DO NOT place the Firefly inside an incubator. DO NOT use Firefly phototherapy with an MTTS infant warmer, or any other warmer as this will cause damage to the Firefly top light.
Auto and car manuals and free pdf automotive manual instructions. Find the user manual you need for your automobile and more at ManualsOnline Whistler Radar Detector XTR-265 User Guide ManualsOnline.com. User manuals, Whistler Radar detector Operating guides and Service manuals. Whistler Manuals; Radar Detector; Whistler Radar Detector manuals Manualslib has more than 185 Whistler Radar Detector manuals. Click on an alphabet below to see the full list of models starting with that letter. Owner's Manual. Owner's Manual. Whistler Manuals; Radar Detector; XTR-265; Whistler XTR-265 Manuals Manuals and User Guides for Whistler XTR-265. We have 2 Whistler XTR-265 manuals available for free PDF download: Owner's Manual. Whistler XTR-265 Owner's Manual (10 pages) Total Band Protection Laser-Radar Detector. Whistler xtr-265 radar detector user manual download. What kind of product do you have? Select a product. Backup Cameras Dash Cameras/DVR Multi Function Unit (MFU) Inspection Cameras Power Inverters Motorcycle Helmet Safety Lights Portable Jump Starter Radar Detectors International Radar Detectors Scanners Tire Pressure Monitoring Systems Show All CR Series Elite Seri.
For the next generationPhototherapy is used to treat hyperbulirubinemia, a common condition in infants, referring to an increase in the amount of bilirubin in the blood. It is characterized by jaundice, a yellowish discoloration of the skin. Phototherapy immerses the patient in a bath of fluorescent light, which breaks up and disperses the excess bilirubin. In the past, clinicians relied on phototherapy units which resembled tanning tables, with the infant placed on a surface illuminated by overhead fluorescent lights. This required the infant to be isolated for long periods of time, with protection pads to shield the eyes from the light.
With the development of flexible fluorescent panels, it was now possible to wrap the infant in the panel during treatment, without eye protection, and still allow the parent to hold the child during part of all of the therapy.
The phototherapy blanket is an alternative to standard phototherapy, which requires the infant to lie under fluorescent bulbs in a hospital incubator while wearing eye patches to prevent possible damage from the light rays. Infants' eyes are not exposed to light under BiliBlanket therapy, and they can be clothed. The blanket also provides more even lighting.
The Ohmeda Biliblanket Plus consists of a halogen lamp in a vented metal housing, which also contains a small fan to disperse heat generated by the lamp. Illumination from the halogen bulb travels through 2400 optical fibers encased in a 1-m-long flexible plastic tube. The optical fibers terminate in a 10 × 15-cm woven pad about 0.64 cm thick. Because the light source is remote, the fiber optic pad generates no heat.
The Ohmeda BiliBlanket is similar to the Healthdyne Wallaby, but has a broader fluorescent panel and a long flexible connector tube that attaches to the main unit. Instead of a 2-position switch, a regulator knob allows incremental increases in the luminescence delivered to the panel. A cooling fan and safety thermostat protect the light source and fiberoptic cable from overheating, and an air flow failure alarm alerts users before overheating occurs.
With the development of flexible fluorescent panels, it was now possible to wrap the infant in the panel during treatment, without eye protection, and still allow the parent to hold the child during part of all of the therapy.
The phototherapy blanket is an alternative to standard phototherapy, which requires the infant to lie under fluorescent bulbs in a hospital incubator while wearing eye patches to prevent possible damage from the light rays. Infants' eyes are not exposed to light under BiliBlanket therapy, and they can be clothed. The blanket also provides more even lighting.
The Ohmeda Biliblanket Plus consists of a halogen lamp in a vented metal housing, which also contains a small fan to disperse heat generated by the lamp. Illumination from the halogen bulb travels through 2400 optical fibers encased in a 1-m-long flexible plastic tube. The optical fibers terminate in a 10 × 15-cm woven pad about 0.64 cm thick. Because the light source is remote, the fiber optic pad generates no heat.
The Ohmeda BiliBlanket is similar to the Healthdyne Wallaby, but has a broader fluorescent panel and a long flexible connector tube that attaches to the main unit. Instead of a 2-position switch, a regulator knob allows incremental increases in the luminescence delivered to the panel. A cooling fan and safety thermostat protect the light source and fiberoptic cable from overheating, and an air flow failure alarm alerts users before overheating occurs.
Biliblanket Meter Ii Instructions
- Apr 21, 2019 Biliblanket Meter Ii User Manual. Biliblanket Light Meter 2 Ge Healthcare. Meter ii bililight bili tester lights dotmed listing 2748385 light meter calibration for non ilt meters sensors filters ohmeda medical bili blanket meter ii manual. Leave a Reply Cancel reply. Your email address will.
- Ohmeda BiliBlanket Light Meter II by GE Healthcare. Quickly and easily measure therapeutic light intensity from various phototherapy systems to make sure your patients are getting the right amount of light; Protect the light meter and carry it around easily with an included carrying strap and a pouch.
FORUMSView All (2)
Ask a New QuestionOhmeda Biliblanket Meter Ii Service Manual
0Replies6 years ago | 6 years agoRepair What may be needed if fan not running and light not working as well? Joker Poker manual Share this! By Atomicboy 4 years ago. This is a lost cause with Steve, but it would be likely more advantageous to have a download for manual for say $5 from his site, I'd support that in a heartbeat, and I bet he would be making much more than what he does now on $20 printed copies. Sound Board for Gottlieb System 1. Video poker joker poker. Joker Poker Quick Search. The electromechanical version of this game is Gottlieb's 1978 'Joker Poker'. We previously showed a date for this game of August 1978. The new date is per Gottlieb documentation. Instruction Manual (with paginated schematics). The Joker Poker coin-operated Pinball by Gottlieb, D. (circa 1978), and it's history and background, photos, repair help, manuals, for sale and wanted lists, and census survey is brought to you by The International Arcade Museum at the Museum fo the Game. Find out everything about Joker Poker (Gottlieb, 1978) pinball machine; General game details, ratings and reviews, photos, videos, high scores, places to play and find. Reply |
-RRikard 7 years ago | 7 years agophototherapy light meter What is the normal meter reading when checking with a meter? Download the vibe manual ebook free. I need to know what the normal range is. Thank you. This is on the biliblanketReply |